INSTALLATION INSTRUCTION:
Prior to concreting, make sure that waterstop is installed in its correct position securely in the concrete structure.
Concrete must be fully compacted around the waterstop to ensure that no voids or porous areas remain.
Internal Application
Aqua-Guard Internally placed Water stops are manufactured with a series of eyelets at a distance of 30 cm along both edges for wiring to nearby reinforcement.
These eyelets should always be used. There should be adequate clearance between waterstop and surrounding reinforcement for wiring and to ensure good compaction.
External Application
Aqua-Guard externally placed Water stops have a reinforced edge nailing flange to give a tear resistant and secure fixing.
Horizontal Installation: When external Waterstop profiles are placed horizontally and supported on blinding or protected waterproofing the profiles do not normally require any fixing.
Vertical Installation: While fixing external Water stops profiles to vertical shuttering use double headed nails fixed through the
reinforced nailing flange into the shuttering /timber formwork. The end of the nail can be cut-off after the concrete is cured to allow following trades to continue such
as waterproofing of coating operations.